F3 - Viton seals
Omit if not required.
Intravane pump series
2520VQH
3525VQH
4525VQH
3520VQH
4520VQH
4535VQH
Pilot designation
S – SAE per ISO 3019/1 (SAE
J744)
Omit for standard pilot.
Geometric displacement -
Shaft end pump
Code = SAE rating (USgpm)
at 1200 r/min and 7
bar (100 psi
FRAME CODE
SIZE (USGPM) CM
3
RIN
3
/R
25VQH 12 40,2 2.45
14 45,4 2.77
17 55,2 3.37
19 61,3 3.74
21 67,5 4.12
35VQH 25 81,6 4.98
30 97,7 5.96
35 112,8 6.88
38 121,6 7.42
45VQH 42 138,7 8.46
47 151,9 9.27
50 162,3 9.90
57 190,2 11.61
60 193,4 11.80
Geometric displacement -
cover end pump
Code= SAE rating (USgpm) at
1200 r/min and 7 bar
(100 psi)
FRAME CODE
SIZE (USGPM) CM
3
RIN
3
/R
**20VQH 5 18,0 1.10
8 27,4 1.67
11 36,4 2.22
12 39,5 2.41
14 45,9 2.80
**25VQH 12 40,2 2.45
14 45,4 2.77
17 55,2 3.37
19 61,3 3.74
21 67,5 4.12
4535VQH 25 81,6 4.98
30 97,7 5.96
35 112,8 6.88
38 121,6 7.42
Mounting & shaft seal
assembly
S – Flange mount and double
shaft seal
Omit for flange mount with
single shaft seal.
Shaft type
With standard pilot, single
shaft seal
1 – Straight keyed
11 – Splined
86 – Straight keyed, heavy duty
With standard pilot, double
shaft seal
123 – Splined (not available on
45**VQ)
130 – Splined (for 45**VQ
only)
With SAE pilot, single or dou-
ble shaft seal
203 – Straight keyed, heavy duty
297 – Splined
Port orientation
(Viewed from cover end of
pump)
All series except 4535VQ
With No.1 outlet opposite
inlet:
AA - No. 2 outlet 135 CCW
from inlet
AB - No. 2 outlet 45 CCW
from inlet
AC - No. 2 outlet 45 CW from
inlet
AD - No. 2 outlet 135 CW
from inlet
With No.1 outlet 90 CCW
from inlet:
BA - No. 2 outlet 135 CCW
from inlet
BB - No. 2 outlet 45 CCW
from inlet
BC - No. 2 outlet 45 CW from
inlet
BD - No. 2 outlet 135 CW
from inlet
With No.1 outlet inline with
inlet:
CA - No. 2 outlet 135 CCW
from inlet
CB - No. 2 outlet 45 CCW
from inlet
CC - No. 2 outlet 45 CW from
inlet
CD - No. 2 outlet 135 CW
from inlet
With No.1 outlet 90 CW from
inlet:
DA - No. 2 outlet 135 CCW
from inlet
DB - No. 2 outlet 45 CCW
from inlet
DC - No. 2 outlet 45 CW from
inlet
DD - No. 2 outlet 135 CW
from inlet
Series 4535VQ
With No.1 outlet opposite
inlet:
AA - No. 2 outlet opposite inlet
AB - No. 2 outlet 90 CCW
from inlet
AC - No. 2 outlet inline with
inlet
AD - No. 2 outlet 90 CW from
inlet
With No.1 outlet 90 CW from
inlet:
BA - No. 2 outlet opposite inlet
BB - No. 2 outlet 90 CCW
from inlet
BC - No. 2 outlet inline with
inlet
BD - No. 2 outlet 90 CW from
inlet
With No.1 outlet inline with
inlet:
CA - No. 2 outlet opposite inlet
CB - No. 2 outlet 90 CCW
from inlet
CC - No. 2 outlet inline inlet
CD - No. 2 outlet 90 CW from
inlet
With No.1 outlet 90 CW from
inlet:
DA - No. 2 outlet opposite inlet
DB - No. 2 outlet 90 CCW
from inlet
DC - No. 2 outlet inline with
inlet
DD - No. 2 outlet 90 CW from
inlet
Design
Shaft rotation
(Viewed form shaft end of
pump)
L - Left hand (counterclockwise)
Omit for right hand.
Note: For options other than listed in the model
code, i.e. shafts, ports, displacements and
mountings, contact your Vickers representative.
11
10
9
8
7
6
4
3
2
1
6 EATON Vickers VQH Series V-PUVN-MC001-E February 2004
Model Codes
Double Pump
(without integral valves)
(F3)-2520VQH (S) 12 A 11 (S)-123 CC 30 (L)
3
1
2
4 5 6 7 8 9 10
11
Port connections
PUMP
SERIES CODE INLET OUTLET NO.1 OUTLET NO. 2
All A SAE 4-bolt flg SAE 4-bolt flg. SAE 4-bolt flg.
All AM* Metric 4-bolt flg. Metric 4-bolt flg. Metric 4-bolt flg.
2520VQH C SAE 4-bolt flg. SAE str. thd. SAE str. thd.
All but
4535VQH E SAE 4-bolt flg. SAE 4-bolt flg. SAE str. thd.
2520VQH F SAE 4-bolt flg. SAE str. thd. SAE 4-bolt flg.
*Same as code “A” port connections, except metric threads for fastening flanges.
5